PMD Budget Calculator
Polarization mode dispersion (PMD) makes the two polarization modes of a pulse arrive at slightly different times. Unlike chromatic dispersion it grows with the square root of length: a G.652.D link designed at 0.20 ps/√km reaches about 1.8 ps mean DGD over 80 km. Use this PMD budget calculator to add fiber and component DGD, compare it with your bit-period tolerance and find the PMD-limited length.
Link and signal
Enter the fiber PMD coefficient and length, any components with their own PMD, and the signal symbol rate.
Fiber
Components
Signal
Mean DGD = √((PMD × √L)² + n × component²). Status fails above the allowed DGD and warns above 80% of it.
Link mean DGD
—Margin to allowed DGD
—PMD is statistical and changes with temperature and handling. Coherent receivers compensate DGD in the DSP; use their datasheet DGD tolerance instead of the NRZ rule.
Limits
Limits
PMD-limited length = (allowed² − Σ component²) / PMD². Instantaneous DGD follows a Maxwellian distribution, so a max-to-mean ratio of about 3 is used for a design maximum. The 80% warning threshold is this tool's screening rule.
Methodology and engineering notes
METHODOLOGY
How to use
- Enter the PMD coefficient (the cable's PMDQ link design value) and the fiber length.
- Add the count and mean DGD of amplifiers, DCMs and other components.
- Enter the symbol rate and the allowed mean DGD as a percentage of the symbol period.
- Read mean DGD, margin and the PMD-limited length.
DGD formula
Fiber mean DGD = PMD coefficient × √L (ps), because PMD accumulates as a random walk. Independent sections add in quadrature: total = √(fiber² + Σ component²). The symbol period is 1000 / symbol rate in GBd (ps); the allowed mean DGD is that period × the chosen percentage.
Worked examples
Worked examples
Worked case: 80 km at 10.3125 GBd
0.20 ps/√km × √80 = 1.789 ps. Four components of 0.1 ps add 0.04 ps²: mean DGD 1.800 ps. The symbol period is 96.97 ps, so the 10% allowance is 9.70 ps and the margin is 7.897 ps (18.6% used). Design maximum ≈ 5.40 ps. The PMD-limited length is about 2,350 km.
Frequently asked questions
FAQ
How do I calculate PMD for a fiber link?
Mean DGD = PMD coefficient × √length. 0.20 ps/√km over 80 km is 0.2 × 8.94 = 1.79 ps. Add component DGD in quadrature.
What is the PMD limit for 10G?
With the common rule of 10% of the bit period, 10.3125 GBd allows about 9.7 ps mean DGD. Older fiber with 0.5 ps/√km reaches that in about 376 km.
Why does PMD grow with the square root of length?
Birefringence changes randomly along the fiber, so the delay accumulates like a random walk, which scales with √L.
What is the difference between PMD and DGD?
DGD is the instantaneous delay between the two polarization modes. PMD is its mean value over wavelength and time, and the coefficient is that mean per √km.
Does PMD matter for coherent 100G or 400G?
Much less. Coherent DSPs compensate tens of ps of DGD, so legacy fiber that limits 10G NRZ can still carry coherent channels.
Recent calculations
PROJECT RECORDS
Standards and references
ENGINEERING REFERENCES
- ITU-T G.652 (08/2024): §7.2 and Table 1/Table 2: maximum PMDQ link design value 0.20 ps/√km for G.652.B/D (M = 20 cables, Q = 0.01%)
- ITU-T G.650.2 (08/2015): definitions and test methods for statistical and non-linear attributes, including PMD
- IEC TR 61282-3 Ed. 2.0 (2006-10): calculation of link PMD – root-sum-square concatenation of fibre and component DGD (clause 2)
The 10%-of-bit-period NRZ rule and the max/mean ratio of about 3 are widely used engineering conventions; confirm the receiver DGD tolerance in the transceiver datasheet. Last reviewed: 2026-10-20.
ENGINEERING WORKFLOW
Continue the engineering workflow
Confirm span length and loss, then check chromatic dispersion and PMD against the transceiver limits.