Chromatic Dispersion Calculator
Chromatic dispersion (CD) spreads each optical pulse because different wavelengths travel at different speeds. Standard G.652 single-mode fiber has about 17 ps/(nm·km) at 1550 nm, so an 80 km span accumulates roughly 1,400 ps/nm. Use this chromatic dispersion calculator to compute D(λ) from the ITU-T G.652 model, total and residual CD, pulse broadening and the longest span your transceiver tolerates.
Fiber and transceiver
Use the G.652 model or enter a datasheet coefficient, then set length, compensation and the receiver CD tolerance.
Source
Dispersion model
Span and tolerance
Residual CD = D × L − compensation. Status fails when |residual| exceeds the tolerance and warns above 80% of it.
Residual CD
—Margin to tolerance
—PMD, nonlinear effects and OSNR are not included. Coherent DSP receivers usually tolerate tens of thousands of ps/nm; use the module datasheet.
Limits and broadening
Limits
Lengths that keep |D × L − C| within the tolerance T lie between (C·sign(D) − T) / |D| and (C·sign(D) + T) / |D|. Without compensation the lower bound is 0, so only the maximum is shown; an over-compensated link (for example D = 17, C = 2,000, T = 400) shows the full window 94.12–141.18 km. Pulse broadening is estimated as |residual CD| × Δλ in ps. The 80% warning threshold is this tool's screening rule, not a standard value.
Methodology and engineering notes
METHODOLOGY
How to use
- Keep the G.652 model or pick “Datasheet value” and enter D from the cable datasheet.
- Enter the wavelength, fiber length and any DCM or FBG compensation.
- Enter the receiver CD tolerance from the transceiver datasheet.
- Read residual CD, margin and the CD-limited length.
Dispersion formula
ITU-T G.652 defines the chromatic dispersion coefficient as D(λ) = (S0/4)·(λ − λ0⁴/λ³) ps/(nm·km), with λ0 between 1300 and 1324 nm and S0 ≤ 0.092 ps/(nm²·km). At 1550 nm with λ0 = 1310 nm and S0 = 0.092 this gives 17.461 ps/(nm·km). Accumulated CD = D × L; residual CD = D × L − compensation.
Worked examples
Worked examples
Worked case: 80 km at 1550 nm
G.652 model, λ0 1310 nm, S0 0.092: D = 17.461 ps/(nm·km). 80 km gives 1,396.8 ps/nm. Against a 1,600 ps/nm receiver the margin is 203.2 ps/nm (87.3% used, warning) and the CD-limited length is 91.63 km. With Δλ = 0.1 nm the broadening is 139.68 ps. Adding 680 ps/nm of compensation leaves 716.8 ps/nm residual.
Frequently asked questions
FAQ
What is the chromatic dispersion of G.652 fiber at 1550 nm?
About 17 ps/(nm·km). The ITU-T G.652 model with λ0 = 1310 nm and S0 = 0.092 gives 17.46 ps/(nm·km); typical cables measure 16.5–18.
How do I calculate total chromatic dispersion?
Multiply the coefficient by the length: CD = D × L. 80 km × 17.46 ps/(nm·km) ≈ 1,397 ps/nm. Subtract any DCM or FBG compensation to get the residual.
What is a typical CD tolerance for 10G optics?
It depends on the module. Directly modulated 10G optics are often specified around 800 ps/nm, while 10G ER/ZR-class optics are often specified around 1,600 ps/nm. Always use the datasheet.
Does chromatic dispersion matter at 1310 nm?
Very little. 1310 nm is close to the zero-dispersion wavelength of G.652 fiber, so D is near 0 there.
Do coherent optics need dispersion compensation?
Usually not. Coherent receivers compensate CD electronically in the DSP and tolerate tens of thousands of ps/nm.
Recent calculations
PROJECT RECORDS
Standards and references
ENGINEERING REFERENCES
- ITU-T G.652 (08/2024): single-mode fibre and cable – §6.10 equation (6-1) chromatic dispersion coefficient D(λ) = (S0/4)(λ − λ0⁴/λ³); λ0 1300–1324 nm and S0 ≤ 0.092 ps/(nm²·km) in clause 8 Table 1 (G.652.B) and Table 2 (G.652.D)
- ITU-T G.650.1 (01/2024): test methods for linear attributes – §6.5 chromatic dispersion measurement, Annex A fitting
- ITU-T G.691 (03/2006): optical interfaces for single-channel STM-64 and other SDH systems with optical amplifiers – §6.3.2.1 maximum chromatic dispersion per application code
- ITU-T G.655 (11/2009): non-zero dispersion-shifted fibre – use the datasheet D for these fibres
Use the datasheet coefficient for G.655, G.654 or vendor fibers; the G.652 model applies to standard single-mode fiber. Last reviewed: 2026-10-20.
ENGINEERING WORKFLOW
Continue the engineering workflow
Confirm span length and loss, then check chromatic dispersion and PMD against the transceiver limits.