A fiber link works when the transmitter-to-receiver optical power window is wider than total path loss. A link budget makes every loss assumption visible.
Margin = available budget − total loss
Worked example: 1:8 × 1:8 PON cascade
For a 1:8 × 1:8 cascade, total split ratio = 8 × 8 = 64 and nominal splitter loss is 21.0 dB. Add 10 km × 0.30 dB/km fiber loss (3.0 dB), six 0.1 dB splices (0.6 dB) and four 0.3 dB connectors (1.2 dB) for 25.8 dB of physical loss, then add 3 dB engineering margin: design loss is 28.8 dB. The 1 dB optical penalty is deducted from the power budget rather than added to loss (GPON C+: 33 dB − 1 dB = 32 dB), which leaves 3.2 dB. Replace planning values with vendor and measured data.
Loss items to record
| Item | Example | Design note |
|---|---|---|
| Fiber attenuation | 0.35 dB/km | Use wavelength specification |
| Connector pair | 0.5 dB each | Include patch panels |
| Fusion splice | 0.1 dB each | Use measured values when available |
| Engineering margin | 2–3 dB | Protects aging and repairs |
Approval workflow
- Record transceiver transmit and receive limits.
- Measure or estimate every passive loss.
- Add margin before comparing to the power budget.
- Check both directions for asymmetric optics.
Frequently asked questions
What does a negative margin mean?
The path loss exceeds the optical budget. Reduce loss or select optics with a larger budget.
Should connector loss be counted once or twice?
Count each mated connector pair in the optical path.